Installations frigorifiques : recommandations relatives a la prévention des risques présentés par les installations frigorifiques fonctionnant a l'ammoniac ou avec des composés chlorofluorés
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071014874</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418114016.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">931013e19840601fra|||| | |00010|fre d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800001530</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">871</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Installations frigorifiques</subfield>
<subfield code="b">: recommandations relatives a la prévention des risques présentés par les installations frigorifiques fonctionnant a l'ammoniac ou avec des composés chlorofluorés</subfield>
</datafield>
<datafield tag="500" ind1=" " ind2=" ">
<subfield code="a">Estas recomendaciones aparecen también publicadas en Cahiers de notes documentaires nº 117, 4e. trimestre 1984, p. 555-561</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">L'article enferme recommandations sur les risques des installations fonctionnant à l'ammoniac ou avec des composés chlorofluorés. Se compose des suivants points: champ d'application, information sur les matériels, installations frigorifiques, salle des machines, chambres froides, autres locaux ou enceintes d'utilisation du froid, équipement de protection et de secours, information et formatio du personnel, contrôle de sécurité</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080629724</subfield>
<subfield code="a">Seguridad e higiene en el trabajo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080550936</subfield>
<subfield code="a">Formación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080619657</subfield>
<subfield code="a">Instalaciones frigoríficas</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080545925</subfield>
<subfield code="a">Amoníaco</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080614942</subfield>
<subfield code="a">Prevención de accidentes</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080639310</subfield>
<subfield code="a">Francia</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080599744</subfield>
<subfield code="a">Accidentes de trabajo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601942</subfield>
<subfield code="a">Industria alimentaria</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080570484</subfield>
<subfield code="a">Riesgo laboral</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080628048</subfield>
<subfield code="a">Equipos de protección individual</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">Travail & sécurité</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="w">MAP20077000314</subfield>
<subfield code="t">Travail & sécurité</subfield>
<subfield code="d">Paris</subfield>
<subfield code="g">nº 6, Juin 1984 ; p. 350-355</subfield>
</datafield>
</record>
</collection>