Détection de mélanges air-ammoniac à faible concentration : étude de cinq explosimètres
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071016346</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418114555.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">931215e19870401fra|||| | |00010|fre d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800002446</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">812.3</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080018719</subfield>
<subfield code="a">Accorsi, A.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Détection de mélanges air-ammoniac à faible concentration</subfield>
<subfield code="b">: étude de cinq explosimètres</subfield>
<subfield code="c">A. Accorsi, J.C. Laforest, P. Huré</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">La détection des fuites d'ammoniac, utilisé dans les installations frigorifiques, est assurée par des explosimètres. Cinq appareils ont été soumis à des essais de qualification et à des essais de longue durée. Quatre des cinq appareils permettent de détecter l'ammoniac aux teneurs choisies pour le déclenchement d'une préalarme et d'une alarme. Les autres performances varient selon le type de détecteur. L'efficacité de la détection des fuites d'ammoniac dépend fortement du choix de l'emplecement des appareils, d'une selection sévère, de la part du constructeur, des capteurs proposés et de l'entretien et du suivi de l'installation</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080629724</subfield>
<subfield code="a">Seguridad e higiene en el trabajo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080620424</subfield>
<subfield code="a">Seguridad contra incendios</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080623470</subfield>
<subfield code="a">Productos tóxicos y peligrosos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080545925</subfield>
<subfield code="a">Amoníaco</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080580650</subfield>
<subfield code="a">Gases inflamables</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080590338</subfield>
<subfield code="a">Detectores de gases</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080543815</subfield>
<subfield code="a">Ensayos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080558291</subfield>
<subfield code="a">Explosiones</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080105051</subfield>
<subfield code="a">Laforest, J.C.</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080102166</subfield>
<subfield code="a">Huré, Philippe</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">Cahiers de notes documentaires</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">Cahiers de notes documentaires</subfield>
<subfield code="d">Paris</subfield>
<subfield code="g">nº 127, 2e. trimestre 1987 ; p. 217-222</subfield>
</datafield>
</record>
</collection>