Search

Asbestos, a hazard after the fire

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071016429</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418114615.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">931221e19930401gbr||||    | |00010|eng d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080129286</subfield>
      <subfield code="a">Dowding, Stwart</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Asbestos, a hazard after the fire</subfield>
      <subfield code="c">Stwart Dowding</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">After a fire has affected a building, it is understandable for an owner to want to return to the premises as soon as possible to start recovery procedures and minimize consequential losses. However, organizations should be aware that there may well be a risk from asbestos fibres after a fire, especially if a building is more than 15 to 25 years old. Buildings of this age tend to contain many different asbestos products in the form of roofing materials, lining and ceiling boards, as well as lagging around hot water pipes, cylinders and boilers. Different types of asbestos may be present, including white (chrysotile), brown (amosite) and blue (crocidolite) asbestos - which all have slightly different properties and varying degrees of toxicity</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080608613</subfield>
      <subfield code="a">Siniestros de incendio</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080550523</subfield>
      <subfield code="a">Edificios</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080542832</subfield>
      <subfield code="a">Amianto</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080552824</subfield>
      <subfield code="a">Toxicidad</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080588953</subfield>
      <subfield code="a">Análisis de riesgos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080565688</subfield>
      <subfield code="a">Fibra mineral</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Fire prevention</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="w">MAP20077000260</subfield>
      <subfield code="t">Fire prevention</subfield>
      <subfield code="d">London</subfield>
      <subfield code="g">nº 258, April 1993 ; p. 26-27</subfield>
    </datafield>
  </record>
</collection>