520  ‎$a‎Measurements under laboratory conditions of the total inward leakages of a compressed air breathing apparatus, worn by 49 firemen, show that 16 of the firemen had minimum protection factors smaller than 2000. The influence of beards, sideburns, long hair and anthropometry on the efficiency of the respiratory protection has been stablished. Based on this performance testing, suggestions for improving the protection level of each fireman could be given, after which all firemen with one exception obtained minimum protection factors higher than 2000