Search

The TLV work-rest regimens for occupational exposure to heat : a review of their development

Fichero PDF / PDF file
MARC record
Tag12Value
LDR  00000nab a2200000 i 4500
001  MAP20071017249
003  MAP
005  20080418115005.0
007  hzruuu---uuuu
008  940209s1979 gbr|||| | |00010|eng d
035  ‎$a‎6800003153
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080286958‎$a‎Malchaire, Jacques B.
24514‎$a‎The TLV work-rest regimens for occupational exposure to heat‎$b‎: a review of their development‎$c‎J.B. Malchaire
520  ‎$a‎A comparison is made between two different approaches for specifying maximum allowable exposure time to heat stress conditions. A rational derivation is given for wet bulb globe thermometer limits for different work-rest regimens that are in close agreement with the ACGIH TLV recommendations. The significance of these limits is discussed. A simpler version of the heat stress index is presented and the advantages of the two methods are compared
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080600488‎$a‎Contaminantes físicos
65011‎$0‎MAPA20080538330‎$a‎Calor
65011‎$0‎MAPA20080568894‎$a‎Estrés térmico
65011‎$0‎MAPA20080560768‎$a‎Temperatura
65011‎$0‎MAPA20080560973‎$a‎Valores TLV
65011‎$0‎MAPA20080560799‎$a‎Termometría
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 1, 1979 ; p. 55-62