Industrial hygiene measurements for organic polluants (acrylonitrile) using passive dosimeters and automated thermal desorption
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071017387</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115035.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940215s1981 gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800003243</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080037772</subfield>
<subfield code="a">Benson, G.B.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Industrial hygiene measurements for organic polluants (acrylonitrile) using passive dosimeters and automated thermal desorption</subfield>
<subfield code="c">G.B. Benson, G.E. Boyce and D.M. Haile</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The laboratory and plant evaluation of a thermally passive dosimeter is described. Acrylonitrile was used as analyte in the evaluation and the gas chromatographic analysis was performed using a nitrogen-specific detector. Good agreement with the standard pump-and-tube method was obtained in plant, suggesting the suitability of the dosimeter for making routine industrial hygiene measurements for acrylonitrile. A prototype automatic thermal desorption system has been constructed and shown to produce repeatable quantitative results with considerable savings in analytical time</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080609894</subfield>
<subfield code="a">Contaminantes orgánicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080554033</subfield>
<subfield code="a">Dosimetría</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080613655</subfield>
<subfield code="a">Control de contaminantes</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080564728</subfield>
<subfield code="a">Acrilonitrilo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080554040</subfield>
<subfield code="a">Dosímetros</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080591960</subfield>
<subfield code="a">Métodos de análisis</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080020897</subfield>
<subfield code="a">Boyce, G.E.</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080025618</subfield>
<subfield code="a">Haile, D.M.</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford [etc.]</subfield>
<subfield code="g">nº 4, 1981 ; p. 367-373</subfield>
</datafield>
</record>
</collection>