Search

The Performance of passive diffusion monitors for organic vapours for personal sampling of painters

Fichero PDF / PDF file
Section: Articles
Title: The Performance of passive diffusion monitors for organic vapours for personal sampling of painters / J.F. Van Der Wal, A. MoerkerkenAuthor: Wal, J.F. van der
Notes: Sumario: Comparative measurements of organic vapour with active and passive monitors showed good agreement in steady-state laboratory chamber tests but considerable discrepancies in field trials on painters, in wich the monitors were worn on opposite lapels under fluctuating conditions of vapour concentration and air movement. This study describes the performance of passive monitors compared with tubes, both worn by paintersRelated records: En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 1, 1984 ; p. 39-47Materia / lugar / evento: Higiene industrial Contaminación atmosférica Control de la contaminación Vapores orgánicos Contaminantes químicos Pinturas Métodos de análisis Muestreos Otros autores: Moerkenken, A.
Secondary titles: Título: The Annals of occupational hygiene
Other categories: 872