Search

The Assessment of a modification to the acetone/triacetin clearing technique as used in the measurement of airborne asbestos dust

Fichero PDF / PDF file
MAP20071017562
Furness, I.W.
The Assessment of a modification to the acetone/triacetin clearing technique as used in the measurement of airborne asbestos dust / I.W. Furness and P.J. Reed
Sumario: An assessment is made of a modification to the acetone/triacetin clearing tecnique which shortens the time required to estimate asbestos fibre concentrations when using the membrane filter method. The modified technique, which is described in the Asbestos International Association reference method but not referred to in the equivalent Australian code, is found to provide acceptable results with no loss of accuracy
En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 1, 1985 ; p. 109-112
1. Higiene industrial . 2. Contaminantes químicos . 3. Amianto . 4. Contaminación atmosférica . 5. Control de la contaminación . 6. MFM . 7. Métodos de análisis . I. Reed, P.J. . II. Title. III. Título: The Annals of occupational hygiene.