Search

Portable gas monitors : some problems of zero drift, response time and selectivity solved with "gas-modifier pumps"

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Portable gas monitors</title>
<subTitle>: some problems of zero drift, response time and selectivity solved with "gas-modifier pumps"</subTitle>
</titleInfo>
<titleInfo type="alternative">
<title>The Annals of occupational hygiene</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080020347">
<namePart>Bergman, I.</namePart>
<nameIdentifier>MAPA20080020347</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">1986</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">The detection and monitoring of toxic gases in industrial atmospheres with the aid of direct-reading instruments presents a number of problems, these may include: zero drift; slow response; lack of selectivity; and insensitivity to some gases. These problems can be ameliorated or overcome by sequentially exposing the sensor to a series of samples, some or all of which have been pumped though gas midifier layers to remove or modify relevant constituents of the gas stream. The requirements of such a system and suitable designs of pumps for application to fixed of portable monitors or alarms are discussed</abstract>
<note type="statement of responsibility">I. Bergman</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080616441">
<topic>Contaminación atmosférica</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080591113">
<topic>Gases contaminantes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080565817">
<topic>Gases tóxicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080621186">
<topic>Control de la contaminación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080551797">
<topic>Muestreos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080590338">
<topic>Detectores de gases</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>The Annals of occupational hygiene</title>
</titleInfo>
<originInfo>
<publisher>Oxford [etc.]</publisher>
</originInfo>
<part>
<text>nº 4, 1986 ; p. 469-479</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940307</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418115156.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071017757</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>