Search

Validation of a high-performance liquid chromatography-fluorescence detection method for the simultaneous quantification of fifteen polycyclic aromatic hydrocarbons

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Validation of a high-performance liquid chromatography-fluorescence detection method for the simultaneous quantification of fifteen polycyclic aromatic hydrocarbons</title>
</titleInfo>
<titleInfo type="alternative">
<title>The Annals of occupational hygiene</title>
</titleInfo>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080193997">
<namePart>Hansen, Ase Marie</namePart>
<nameIdentifier>MAPA20080193997</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">1991</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">The present study describes the validation of a new method for the simultaneous detection of 15 of the 16 reference PAH compounds. This is based on fluorescence detection in combination with multiple changes both in excitation and emission wavelengths. One of the 16 reference PAH (polycyclic aromatic hidrocarbon) compounds (acenaphthylene) cannot be excited, hence this compound was excluded from the study. The results of the new method are compared with those of Dong and Greenberg (1988) and of Wise... [et al.] (1991)</abstract>
<note type="statement of responsibility">Ase Marie Hansen... [et al.]</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080630195">
<topic>Hidrocarburo aromático policíclico</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080591960">
<topic>Métodos de análisis</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080616441">
<topic>Contaminación atmosférica</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080600662">
<topic>Cromatografía líquida</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080601492">
<topic>Estudios comparativos</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>The Annals of occupational hygiene</title>
</titleInfo>
<originInfo>
<publisher>Oxford [etc.]</publisher>
</originInfo>
<part>
<text>nº 6, December 1991 ; p. 603-611</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940314</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418115228.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071017889</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>