Search

Performance characteristics of control devices to maintain constant face velocity for laboratory exhaust hoods

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071019339</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418115754.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940525e19890901usa||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013184</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Performance characteristics of control devices to maintain constant face velocity for laboratory exhaust hoods</subfield>
      <subfield code="c">Richard P. Garrison... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Performance characteristics were investigated for six commercial devices designed to maintain constant face velocity (FV) with changing sash position for a laboratory exhaust hood. Testing involved displacement of the hood sash upward and downward and monitoring hood and controller performance. Some FV deviations were too great to assure adequate control for potential exposures to highly toxic materials</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080625054</subfield>
      <subfield code="a">Sustancias tóxicas y peligrosas</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080621186</subfield>
      <subfield code="a">Control de la contaminación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080560997</subfield>
      <subfield code="a">Ventilación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080552923</subfield>
      <subfield code="a">Velocidad</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080537210</subfield>
      <subfield code="a">Aire</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080563134</subfield>
      <subfield code="a">Laboratorios</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080264116</subfield>
      <subfield code="a">Garrison, Richard P.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">American Industrial Hygiene Association journal</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">American Industrial Hygiene Association journal</subfield>
      <subfield code="d">Akron, Ohio</subfield>
      <subfield code="g">Vol. 50, nº 9, September 1989 ; p. 501-504</subfield>
    </datafield>
  </record>
</collection>