The Use of detector tubes following ASTM method F-739-85 for measuring permeation resistance of clothing
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Tag | 1 | 2 | Value |
---|---|---|---|
LDR | 00000nab a2200000 i 4500 | ||
001 | MAP20071019342 | ||
003 | MAP | ||
005 | 20080418115754.0 | ||
007 | hzruuu---uuuu | ||
008 | 940525e19890601usa|||| | |00010|eng d | ||
035 | $a6800013187 | ||
040 | $aMAP$bspa | ||
084 | $a872 | ||
100 | 1 | $0MAPA20080232375$aSarner, Stanley F. | |
245 | 1 | 4 | $aThe Use of detector tubes following ASTM method F-739-85 for measuring permeation resistance of clothing$cStanley F. Sarner and Norman W. Henry |
520 | $aThe use of detector tubes as the analytical method for the measurement of permeation according to ASTM method F-739-85 has been investigated. This analytical method is rapid, can be run with multiple samples simultaneously, and has the advantage of not requiring elaborate or expensive analytical equipment which requires calibration. The systems investigated were neoprene/methanol and neoprene/acetone. It is cocluded that detector tubes provide an analytical method for permeation testing which can be expected to give results comparable to those from gas chromatographic analytical systems | ||
650 | 1 | 1 | $0MAPA20080585679$aHigiene industrial |
650 | 1 | 1 | $0MAPA20080605278$aContaminantes químicos |
650 | 1 | 1 | $0MAPA20080628048$aEquipos de protección individual |
650 | 1 | 1 | $0MAPA20080539733$aRopas |
650 | 1 | 1 | $0MAPA20080566821$aPermeabilidad |
650 | 1 | 1 | $0MAPA20080618223$aResistencia de materiales |
650 | 1 | 1 | $0MAPA20080594824$aASTM method F-739-85 |
650 | 1 | 1 | $0MAPA20080586331$aMétodos analíticos |
700 | 1 | $0MAPA20080165741$aHenry, Norman W. | |
740 | 0 | $aAmerican Industrial Hygiene Association journal | |
773 | 0 | $tAmerican Industrial Hygiene Association journal$dAkron, Ohio$gVol. 50, nº 6, June 1989 ; p. 298-302 |