"Worst case" aerosol testing parameters. I : sodium chloride and dioctyl phthalate aerosol filter efficiency as a function of particle size and flow rate
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
| Tag | 1 | 2 | Value |
|---|---|---|---|
| LDR | 00000nab a2200000 i 4500 | ||
| 001 | MAP20071019423 | ||
| 003 | MAP | ||
| 005 | 20080418115811.0 | ||
| 007 | hzruuu---uuuu | ||
| 008 | 940601e19890501usa|||| | |00010|eng d | ||
| 035 | $a6800013111 | ||
| 040 | $aMAP$bspa | ||
| 084 | $a872 | ||
| 100 | 1 | $0MAPA20080255510$aStevens, Gregory A. | |
| 245 | 1 | 1 | $a"Worst case" aerosol testing parameters. I$b: sodium chloride and dioctyl phthalate aerosol filter efficiency as a function of particle size and flow rate$cGregory A. Stevens and Ernest S. Moyer |
| 520 | $aThe object of this study was to determine the optimum aerosol particle size for testing particulate respirator filters and to determine how this varies as a function of test flow rate. Challenge aerosol parameters, such as particle size, density, shape, electrical charge, and flow rate, are influential in determining the filter's efficiency | ||
| 650 | 1 | 1 | $0MAPA20080585679$aHigiene industrial |
| 650 | 1 | 1 | $0MAPA20080616441$aContaminación atmosférica |
| 650 | 1 | 1 | $0MAPA20080605278$aContaminantes químicos |
| 650 | 1 | 1 | $0MAPA20080549534$aAerosoles |
| 650 | 1 | 1 | $0MAPA20080621186$aControl de la contaminación |
| 650 | 1 | 1 | $0MAPA20080586355$aMétodos de control |
| 650 | 1 | 1 | $0MAPA20080543969$aFiltros |
| 650 | 1 | 1 | $0MAPA20080568368$aCloruro sódico |
| 650 | 1 | 1 | $0MAPA20080580070$aDioctyl phthalate |
| 700 | 1 | $0MAPA20080172275$aMoyer, Ernest S. | |
| 740 | 0 | $aAmerican Industrial Hygiene Association journal | |
| 773 | 0 | $tAmerican Industrial Hygiene Association journal$dAkron, Ohio$gVol. 50, nº 5, May 1989 ; p. 257-264 |