Efficiency and effectiveness of stoop and squat lifting at different frequencies
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071019491</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115824.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940530e19910501gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013226</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">875</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Efficiency and effectiveness of stoop and squat lifting at different frequencies</subfield>
<subfield code="c">E. Welbergen... [et al.]</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The study investigated the effects or frequency and technique of repetitive lifting of a barbell on the relationship between mean power output and energy cost in 9 male power-lifters. Oxygen uptake was measured directly and continuously and power output was deduced from film analysis using an inverse dynamic analysis. Power output and oxygen consumption were significantly greater for squat than for stoop lifting at the same frequency</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080550653</subfield>
<subfield code="a">Ergonomía</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080557348</subfield>
<subfield code="a">Biomecánica</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080545048</subfield>
<subfield code="a">Postura</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080557973</subfield>
<subfield code="a">Efectividad</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080589462</subfield>
<subfield code="a">Carga de materiales</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080584252</subfield>
<subfield code="a">Consumo de oxígeno</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080087630</subfield>
<subfield code="a">Welbergen, E.</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">Ergonomics</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">Ergonomics</subfield>
<subfield code="d">London and Washington</subfield>
<subfield code="g">Vol. 34, nº 5, May 1991 ; p. 613-624</subfield>
</datafield>
</record>