Effect of ventilation on ammonia levels in cowhouses
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Tag | 1 | 2 | Value |
---|---|---|---|
LDR | 00000nab a2200000 i 4500 | ||
001 | MAP20071019974 | ||
003 | MAP | ||
005 | 20080418120013.0 | ||
007 | hzruuu---uuuu | ||
008 | 940617e19931101usa|||| | |00010|eng d | ||
035 | $a6800013401 | ||
040 | $aMAP$bspa | ||
084 | $a872 | ||
100 | 1 | $0MAPA20080106027$aLinnainmaa, M. | |
245 | 1 | 0 | $aEffect of ventilation on ammonia levels in cowhouses$cM. Linnainmaa, K. Louhelainen, T. Eskelinen |
520 | $aThe effect of ventilation on concentrations of ammonia in typical Finnish cowhouses was investigated. Temperature, relative humidity, and concentration of carbon dioxide also were measured. A tracer-gas technique and multipoint equipment measured ventilation. Samples for airborne ammonia were collected in impinger flasks and analyzed by a gas-specific electrode | ||
650 | 1 | 1 | $0MAPA20080585679$aHigiene industrial |
650 | 1 | 1 | $0MAPA20080605278$aContaminantes químicos |
650 | 1 | 1 | $0MAPA20080625054$aSustancias tóxicas y peligrosas |
650 | 1 | 1 | $0MAPA20080545925$aAmoníaco |
650 | 1 | 1 | $0MAPA20080560997$aVentilación |
650 | 1 | 1 | $0MAPA20080544096$aGranjas |
700 | 1 | $0MAPA20080139254$aLouhelainen, K. | |
700 | 1 | $0MAPA20080068158$aEskelinen, T. | |
740 | 0 | $aAmerican Industrial Hygiene Association journal | |
773 | 0 | $tAmerican Industrial Hygiene Association journal$dFairfax, Virginia$gVol. 54, nº 11, November 1993 ; p. 678-682 |