Search

Establishment of an air-quality indicator for bus diesel exhaust in garages

Fichero PDF / PDF file
Section: Articles
Title: Establishment of an air-quality indicator for bus diesel exhaust in garages / Jacques Lavoie... [et al.]
Notes: Sumario: This study simultaneously measured levels of CO2, CO, NO, NO2, and total particulates in three bus garages of a mass transit company, using standard methods. A net CO2 concentration of 400 ppm can therefore be proposed as an indicator of the maintenance of air quality in these garages. While the specific relationship between CO2 levels will vary as a function of operating conditions in specific garages, this approach can nevertheless serve as the basis of air-quality monitoring in other garages where diesel engines are in operationRelated records: En: American Industrial Hygiene Association journal. - Fairfax, Virginia. - Vol. 54, nº 8, August 1993 ; p. 426-431Materia / lugar / evento: Higiene industrial Contaminantes químicos Dióxido de carbono Contaminación atmosférica Control de la contaminación Calidad del aire Motores diesel Garajes Otros autores: Lavoie, Jacques
Secondary titles: Título: American Industrial Hygiene Association journal
Other categories: 872