Search

The Use of inductive plethysmography in the study of the ventilatory effects of respirator wear

Fichero PDF / PDF file
MAP20071020015
Stark, Gregory P.
The Use of inductive plethysmography in the study of the ventilatory effects of respirator wear / Gregory P. Stark, Thomas K. Hodous and John L. Hankinson
Sumario: The authors recently developed an ambulatory system, in which a self-contained respiratory inductive plethysmograph (RIP) was used, to measure noninvasively the volume and time components of breathing. Since it does not use nasal or oral devices, such a system is particularly suitable for use in studying the effects of respiratory protective masks on respiratory parameters. In order to validate this portable system, 22 healthy subjects were exercised on a treadmill; RIP and pneumotachographic minute ventilation measurements were compared
En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 49, nº 8, August 1988 ; p. 401-408
1. Higiene industrial . 2. Contaminantes químicos . 3. Equipos respiratorios . 4. Ventilación pulmonar . 5. Vías respiratorias . 6. Ensayos . 7. Pletismógrafo . I. Hodous, Thomas K. . II. Hankinson, John L. . III. Title. IV. Título: American Industrial Hygiene Association journal.