Biological safety cabinets : decontamination or sterilization with paraformaldehyde
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071020019</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120044.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940623e19880601usa|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013446</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Biological safety cabinets</subfield>
<subfield code="b">: decontamination or sterilization with paraformaldehyde</subfield>
<subfield code="c">Richard Fink... [et al.]</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Bacillus subtilis var. niger spores were used to determine the exposure time for formaldehyde decontamination of biological safety cabinets. Formaldehyde contact times less than 3 hr were insufficient for sterilization. A contact time of 4 hr or more resulted in a reproducible killing of the spore strips placed inside the cabinets. At 6 hr sufficient formaldehyde had diffused through the high efficiency particulate air (HEPA) filter to sterilize the strips with lower spore counts. A minimum of 5 to 6 logs of killing were observed after 4 to 6 hr of treatment</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080613617</subfield>
<subfield code="a">Contaminantes biológicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080562595</subfield>
<subfield code="a">Formaldehido</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080568887</subfield>
<subfield code="a">Esterilización</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080582241</subfield>
<subfield code="a">Recintos cerrados</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080068660</subfield>
<subfield code="a">Fink, Richard</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">American Industrial Hygiene Association journal</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">American Industrial Hygiene Association journal</subfield>
<subfield code="d">Akron, Ohio</subfield>
<subfield code="g">Vol. 49, nº 6, June 1988 ; p. 277-279</subfield>
</datafield>
</record>
</collection>