Search

Method for the evaluation of the permeation characteristics of protective glove materials

Fichero PDF / PDF file
MARC record
Tag12Value
LDR  00000nab a2200000 i 4500
001  MAP20071020022
003  MAP
005  20080418120044.0
007  hzruuu---uuuu
008  940623e19880601usa|||| | |00010|eng d
035  ‎$a‎6800013449
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080167295‎$a‎Jencen, David A.
24510‎$a‎Method for the evaluation of the permeation characteristics of protective glove materials‎$c‎David A. Jencen and James K. Hardy
520  ‎$a‎A method is described to evaluate the permeation characteristics of glove materials by chemical solvents. The collecting medium is continuously monitored by a flame ionization detector of a gas chromatographic. Inmediately following a steady-state condition, quantitative data are acquired on-line by a computer. A two-position GC sampling valve and computer-controlled data acquisition and analysis require minimal operator attention. A modification of the procedure which allowed the determination of the effect of temperature on permeation for 4 glove/solvent pairs was evaluated
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080613839‎$a‎Disolventes industriales
65011‎$0‎MAPA20080628048‎$a‎Equipos de protección individual
65011‎$0‎MAPA20080601836‎$a‎Guantes de protección
65011‎$0‎MAPA20080566821‎$a‎Permeabilidad
65011‎$0‎MAPA20080602574‎$a‎Métodos de evaluación
65011‎$0‎MAPA20080615543‎$a‎Técnicas cromatográficas
7001 ‎$0‎MAPA20080133825‎$a‎Hardy, James K.
7400 ‎$a‎American Industrial Hygiene Association journal
7730 ‎$t‎American Industrial Hygiene Association journal‎$d‎Akron, Ohio‎$g‎Vol. 49, nº 6, June 1988 ; p. 293-300