The Use of a transportable Fourier transform infrared (FTIR) spectrometer for the direct measurement of solvents in breath and ambient air. I : methanol

Fichero PDF / PDF file
MARC record
Tag12Value
LDR  00000nab a2200000 i 4500
001  MAP20071020111
003  MAP
005  20080418120106.0
007  hzruuu---uuuu
008  940630e19920401usa|||| | |00010|eng d
035  ‎$a‎6800013111
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
24514‎$a‎The Use of a transportable Fourier transform infrared (FTIR) spectrometer for the direct measurement of solvents in breath and ambient air. I‎$b‎: methanol‎$c‎Alfred Franzblau... [et al.]
520  ‎$a‎This article reports on preliminary tests of FTIR spectroscopy for use as a breath analyzer, which may be an improvement over previous analysis methods. Four human subjects were exposed to methanol under controlled conditions. End-expiratory air and blood were collected before, during, and after exposure and analyzed for methanol
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080545673‎$a‎Vapores
65011‎$0‎MAPA20080557904‎$a‎Disolventes
65011‎$0‎MAPA20080582203‎$a‎Rayos infrarrojos
65011‎$0‎MAPA20080568832‎$a‎Espectroscopia
65011‎$0‎MAPA20080537562‎$a‎FTIR
65011‎$0‎MAPA20080591960‎$a‎Métodos de análisis
65011‎$0‎MAPA20080613655‎$a‎Control de contaminantes
65011‎$0‎MAPA20080551797‎$a‎Muestreos
65011‎$0‎MAPA20080544584‎$a‎Metanol
65011‎$0‎MAPA20080554859‎$a‎Inhalación
7001 ‎$0‎MAPA20080191924‎$a‎Franzblau, Alfred
7400 ‎$a‎American Industrial Hygiene Association journal
7730 ‎$t‎American Industrial Hygiene Association journal‎$d‎Akron, Ohio‎$g‎Vol. 53, nº 4, April 1992 ; p. 221-227