An Air-curtain fume cabinet
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Tag | 1 | 2 | Value |
---|---|---|---|
LDR | 00000nab a2200000 i 4500 | ||
001 | MAP20071020114 | ||
003 | MAP | ||
005 | 20080418120107.0 | ||
007 | hzruuu---uuuu | ||
008 | 940628e19921001usa|||| | |00010|eng d | ||
035 | $a6800013111 | ||
040 | $aMAP$bspa | ||
084 | $a872 | ||
100 | 1 | $0MAPA20080097806$aEtkin, Bernard | |
245 | 1 | 3 | $aAn Air-curtain fume cabinet$cBernard Etkin and W.D. Mckinney |
520 | $aThis paper reports a theorical and experimental investigation of the use of an air curtain the fumes in a fume cabinet. It was motivated by the susceptibility of conventional fume hoods to loss of containment in the presence of crossdrafts | ||
650 | 1 | 1 | $0MAPA20080585679$aHigiene industrial |
650 | 1 | 1 | $0MAPA20080605278$aContaminantes químicos |
650 | 1 | 1 | $0MAPA20080616441$aContaminación atmosférica |
650 | 1 | 1 | $0MAPA20080565954$aHumos tóxicos |
650 | 1 | 1 | $0MAPA20080604967$aCampanas de extracción |
650 | 1 | 1 | $0MAPA20080590895$aExtracción de humos |
650 | 1 | 1 | $0MAPA20080613655$aControl de contaminantes |
650 | 1 | 1 | $0MAPA20080552923$aVelocidad |
650 | 1 | 1 | $0MAPA20080584412$aCorrientes de aire |
650 | 1 | 1 | $0MAPA20080539948$aTests |
650 | 1 | 1 | $0MAPA20080607289$aMétodos experimentales |
700 | 1 | $0MAPA20080139674$aMacKinney, W.D. | |
740 | 0 | $aAmerican Industrial Hygiene Association journal | |
773 | 0 | $tAmerican Industrial Hygiene Association journal$dAkron, Ohio$gVol. 53, nº 10, October 1992 ; p. 625-631 |