Search

Use of fluidizing bed aerosol generators to stablish a dust mixture of two substances at a fixed ratio for inhalation toxicity studies

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071020196</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120127.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940629e19920801usa||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013498</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Use of fluidizing bed aerosol generators to stablish a dust mixture of two substances at a fixed ratio for inhalation toxicity studies</subfield>
      <subfield code="c">R.N. Shiotsuka... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">A method was developed to use two fluidizing bed generators to deliver a mixture of 1 mg cobalt + 15 mg tungsten carbide/m3 to an inhalation exposure chamber with the output from the cobalt generator split to provide the same cobalt concentration to a cobalt-only chamber. To provide a more uniform delivery of material and to minimize the amount of starting dust needed, a subsystem that produced time bursts of compressed air was used to prevent the accumulation fo dust along the aerosol transport tubes. The addition of an electrostatic precipitator placed in the exhaust lines reduced the amount of dust delivered to the high-efficiency particulate air filters, thereby reducing the number of filter changes</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080543471</subfield>
      <subfield code="a">Cobalto</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080595074</subfield>
      <subfield code="a">Carburo de tungsteno</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080554859</subfield>
      <subfield code="a">Inhalación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080549534</subfield>
      <subfield code="a">Aerosoles</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080552824</subfield>
      <subfield code="a">Toxicidad</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080616441</subfield>
      <subfield code="a">Contaminación atmosférica</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080148256</subfield>
      <subfield code="a">Shiotsuka, R.N.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">American Industrial Hygiene Association journal</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">American Industrial Hygiene Association journal</subfield>
      <subfield code="d">Akron, Ohio</subfield>
      <subfield code="g">Vol. 53, nº 8, August 1992 ; p. 510-513</subfield>
    </datafield>
  </record>
</collection>