Search

A Feasibility study of quantitative respirator fit testing by controlled negative pressure

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<nonSort xml:space="preserve">A  </nonSort>
<title>Feasibility study of quantitative respirator fit testing by controlled negative pressure</title>
</titleInfo>
<titleInfo type="alternative">
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080316594">
<namePart>Crutchfield, Clifton D.</namePart>
<nameIdentifier>MAPA20080316594</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080130145">
<namePart>Eroh, Martin P.</namePart>
<nameIdentifier>MAPA20080130145</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080161743">
<namePart>Ert, Mark D. van</namePart>
<nameIdentifier>MAPA20080161743</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">usa</placeTerm>
</place>
<dateIssued encoding="marc">1991</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">The feasibility of using a direct measure of respirator leakage flow rate as a quantitative index of respirator face seal fit has been explored through the use of a new controlled negative pressure method. The method is based on exhausting air from a temporarily sealed respirator facepiece at a rate sufficient to generate and then sustain a constant negative pressure inside the facepiece while the wearer holds his breath</abstract>
<note type="statement of responsibility">Clifton D. Crutchfield, Martin P. Eroh, Mark D. Van Ert</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080601393">
<topic>Equipos respiratorios</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080619831">
<topic>Mascarillas autofiltrantes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080548094">
<topic>Máscaras</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080586355">
<topic>Métodos de control</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080539948">
<topic>Tests</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>American Industrial Hygiene Association journal</title>
</titleInfo>
<originInfo>
<publisher>Akron, Ohio</publisher>
</originInfo>
<part>
<text>Vol. 52, nº 4, April 1991 ; p. 172-176</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">940701</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418120151.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071020312</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>