Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
MAP20071020351Bellin, PeterAerosol penetration through respirator exhalation valves / Peter Bellin, William C. HindsSumario: Aerosol penetration into a mask can occur by three routes: filter penetration, facial seal leaks, and exhalation valve leakage. The first two mechanisms usually are the most important, although the latter can be significant in certain circumstances, such as when the valve is dirty or malfunctioning. This paper adressess the nature and extent of exhalation valve leakage, that is, back leakage of outside air through the exhalation valve as it closes and seals during inhalationEn: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 51, nº 10, October 1990 ; p. 555-5601. Higiene industrial. 2. Contaminantes químicos. 3. Sustancias tóxicas y peligrosas. 4. Aerosoles. 5. Inhalación. 6. Máscaras. 7. Equipos respiratorios. 8. Válvulas. I. Hinds, William C.. II. Title. III. Título: American Industrial Hygiene Association journal.