Calculation of the performance of activated carbon at high relative humidities
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071020456</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120228.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940624e19871101usa|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013455</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080275969</subfield>
<subfield code="a">Underhill, Dwight W.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Calculation of the performance of activated carbon at high relative humidities</subfield>
<subfield code="c">Dwight W. Underhill</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The Dubinin-Radushkevich potential theory was extended to include a term giving the effect of relative humidity on the uptake of adsorbate. This extended equation permits the adsorptive capacity of the activated charcoal in a respirator cartridge to be estimated for any combination of temperature, relative humidity, and concentration of contaminant</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080544195</subfield>
<subfield code="a">Humedad</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080571528</subfield>
<subfield code="a">Carbón activado</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601393</subfield>
<subfield code="a">Equipos respiratorios</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080592042</subfield>
<subfield code="a">Modelos matemáticos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080607289</subfield>
<subfield code="a">Métodos experimentales</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080554125</subfield>
<subfield code="a">Ecuaciones</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">American Industrial Hygiene Association journal</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">American Industrial Hygiene Association journal</subfield>
<subfield code="d">Akron, Ohio</subfield>
<subfield code="g">Vol. 48, nº 11, November 1987 ; p. 909-913</subfield>
</datafield>
</record>
</collection>