Search

Contaminant breakthrough : a theoretical study of charcoal sampling tubes

Fichero PDF / PDF file
MAP20071020469
Yoon, Young Hee
Contaminant breakthrough : a theoretical study of charcoal sampling tubes / Young Hee Yoon and James H. Nelson
Sumario: A previously developed theoretical model was applied to investigate contaminant breakthrough on charcoal sampling tubes. Associated with the model are two important theoretical parameters. These parameters are k' (a ratte constant) and t (the time required 50% contaminant breakthrough). In this study, values of k' and t were determined for n-heptane at five different concentration levels in air
En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 51, nº 6, June 1990 ; p. 319-325
1. Higiene industrial . 2. Contaminantes químicos . 3. Contaminación atmosférica . 4. Control de la contaminación . 5. Muestreador . 6. Muestreos . 7. Modelos matemáticos . I. Nelson, James H. . II. Title. III. Título: American Industrial Hygiene Association journal.