Contaminant breakthrough : a theoretical study of charcoal sampling tubes
<?xml version="1.0" encoding="UTF-8" standalone="no"?>
<rdf:RDF xmlns:rdf="http://www.w3.org/1999/02/22-rdf-syntax-ns#" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<rdf:Description>
<dc:creator>Yoon, Young Hee</dc:creator>
<dc:creator>Nelson, James H.</dc:creator>
<dc:date>1990-06-01</dc:date>
<dc:description xml:lang="es">Sumario: A previously developed theoretical model was applied to investigate contaminant breakthrough on charcoal sampling tubes. Associated with the model are two important theoretical parameters. These parameters are k' (a ratte constant) and t (the time required 50% contaminant breakthrough). In this study, values of k' and t were determined for n-heptane at five different concentration levels in air</dc:description>
<dc:identifier>https://documentacion.fundacionmapfre.org/documentacion/publico/es/bib/48175.do</dc:identifier>
<dc:language>eng</dc:language>
<dc:rights xml:lang="es">InC - http://rightsstatements.org/vocab/InC/1.0/</dc:rights>
<dc:subject xml:lang="es">Higiene industrial</dc:subject>
<dc:subject xml:lang="es">Contaminantes químicos</dc:subject>
<dc:subject xml:lang="es">Contaminación atmosférica</dc:subject>
<dc:subject xml:lang="es">Control de la contaminación</dc:subject>
<dc:subject xml:lang="es">Muestreador</dc:subject>
<dc:subject xml:lang="es">Muestreos</dc:subject>
<dc:subject xml:lang="es">Modelos matemáticos</dc:subject>
<dc:type xml:lang="es">Artículos y capítulos</dc:type>
<dc:title xml:lang="es">Contaminant breakthrough : a theoretical study of charcoal sampling tubes</dc:title>
<dc:title xml:lang="es">Título: American Industrial Hygiene Association journal</dc:title>
<dc:relation xml:lang="es">En: American Industrial Hygiene Association journal. - Akron, Ohio. - Vol. 51, nº 6, June 1990 ; p. 319-325</dc:relation>
</rdf:Description>