Search

Numerical calculation of air flow fields generated by exhaust openings

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071020499</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120239.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940713e19931001gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013617</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">872</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080074920</subfield>
      <subfield code="a">Kulmala, Ilpo</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Numerical calculation of air flow fields generated by exhaust openings</subfield>
      <subfield code="c">Ilpo Kulmala</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">The applicability of numerical simulations for the prediction of the flow field of exhaust openings was examined. Numerical calculations were conducted for two dimensional plain and flanged circular openings and three-dimensional plain and flanged rectangular openings. The air flows were simulated by the FLUENT computer code based on the finite difference method, using the k-e turbulence model. The accuracy of the simulations was determined by comparing the predicted results with potential flow solutions and experimental results. For flanged openings, the agreement between numerical simulations and potential flow solutions was good. For plain openings the agreement was satisfactory</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080616441</subfield>
      <subfield code="a">Contaminación atmosférica</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080621186</subfield>
      <subfield code="a">Control de la contaminación</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080584412</subfield>
      <subfield code="a">Corrientes de aire</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080546373</subfield>
      <subfield code="a">Cálculos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080592042</subfield>
      <subfield code="a">Modelos matemáticos</subfield>
    </datafield>
    <datafield tag="740" ind1="4" ind2=" ">
      <subfield code="a">The Annals of occupational hygiene</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">The Annals of occupational hygiene</subfield>
      <subfield code="d">Oxford [etc.]</subfield>
      <subfield code="g">nº 5, October 1993 ; p. 451-467</subfield>
    </datafield>
  </record>
</collection>