Measurement of outdoor and recirculated air percentages by carbon dioxide tracer
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071020603</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418120305.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940720e19940601usa|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800013474</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080142933</subfield>
<subfield code="a">Olcerst, Robert</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Measurement of outdoor and recirculated air percentages by carbon dioxide tracer</subfield>
<subfield code="c">Robert Olcerst</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">This article presents a technique to extend the utility of carbon dioxide dataloggers, such as the Metrosonic Aq-501, to provide information on the percentages of both outside aire and recirculated air in a ventilated compartment. An electronic timed sampling valve is used to alternately collect air from the room supply and from the recirculating airstream. The timed valve provides a dataset for each location that can be used to calculate the percentages of outside and recirculated air. The technique uses ambient carbon dioxide as a natural tracer gas. The carbon dioxide tracer technique can be used when the psychometric temperature method for calculating outside air percentage is indeterminate because the return air and outdoor air temperatures are equal</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080584740</subfield>
<subfield code="a">Dióxido de carbono</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080616441</subfield>
<subfield code="a">Contaminación atmosférica</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560997</subfield>
<subfield code="a">Ventilación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080612597</subfield>
<subfield code="a">Sistemas de ventilación</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080591960</subfield>
<subfield code="a">Métodos de análisis</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">American Industrial Hygiene Association journal</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">American Industrial Hygiene Association journal</subfield>
<subfield code="d">Fairfax, Virginia</subfield>
<subfield code="g">Vol. 55, nº 6, June 1994 ; p. 525-528</subfield>
</datafield>
</record>
</collection>