A Personal conditioning system based on a liquid-conditioned vest and a thermoelectric supply system

Fichero PDF / PDF file
MARC record
Tag12Value
LDR  00000nab a2200000 i 4500
001  MAP20071020667
003  MAP
005  20080418120324.0
007  hzruuu---uuuu
008  940719e19880701gbr|||| | |00010|eng d
035  ‎$a‎6800013672
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎875
24512‎$a‎A Personal conditioning system based on a liquid-conditioned vest and a thermoelectric supply system‎$c‎G. Richardson... [et al.]
520  ‎$a‎A personal conditioning system has been developed for RFA air crew. It employs a liquid-conditioned vest covering the torso and upper arms. The liquid sypply system uses thermoelectric elements to provide either heating or cooling. The system has been subjected to a number of environmental tests. It has been shown to be capable of extracting 150 W from a human subject in an ambient temperature of 40ºC and at altitudes of 10000 feet. Further physiological tests have shown that this is sufficient to control body temperature in environments where heat stress would otherwise have occurred
65011‎$0‎MAPA20080550653‎$a‎Ergonomía
65011‎$0‎MAPA20080628048‎$a‎Equipos de protección individual
65011‎$0‎MAPA20080539733‎$a‎Ropas
65011‎$0‎MAPA20080567149‎$a‎Refrigerantes
65011‎$0‎MAPA20080571672‎$a‎Confort térmico
65011‎$0‎MAPA20080574567‎$a‎Ambiente térmico
65011‎$0‎MAPA20080626426‎$a‎Sistemas de aire acondicionado
65011‎$0‎MAPA20080560768‎$a‎Temperatura
7001 ‎$0‎MAPA20080113520‎$a‎Richardson, G.
7400 ‎$a‎Ergonomics
7730 ‎$t‎Ergonomics‎$d‎London [etc.]‎$g‎Vol. 31, nº 7, July 1988 ; p. 1041-1047