Search

A Personal conditioning system based on a liquid-conditioned vest and a thermoelectric supply system

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071020667</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418120324.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940719e19880701gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800013672</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">875</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="2">
      <subfield code="a">A Personal conditioning system based on a liquid-conditioned vest and a thermoelectric supply system</subfield>
      <subfield code="c">G. Richardson... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">A personal conditioning system has been developed for RFA air crew. It employs a liquid-conditioned vest covering the torso and upper arms. The liquid sypply system uses thermoelectric elements to provide either heating or cooling. The system has been subjected to a number of environmental tests. It has been shown to be capable of extracting 150 W from a human subject in an ambient temperature of 40ºC and at altitudes of 10000 feet. Further physiological tests have shown that this is sufficient to control body temperature in environments where heat stress would otherwise have occurred</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080550653</subfield>
      <subfield code="a">Ergonomía</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080628048</subfield>
      <subfield code="a">Equipos de protección individual</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080539733</subfield>
      <subfield code="a">Ropas</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080567149</subfield>
      <subfield code="a">Refrigerantes</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080571672</subfield>
      <subfield code="a">Confort térmico</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080574567</subfield>
      <subfield code="a">Ambiente térmico</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080626426</subfield>
      <subfield code="a">Sistemas de aire acondicionado</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080560768</subfield>
      <subfield code="a">Temperatura</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080113520</subfield>
      <subfield code="a">Richardson, G.</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Ergonomics</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">Ergonomics</subfield>
      <subfield code="d">London [etc.]</subfield>
      <subfield code="g">Vol. 31, nº 7, July 1988 ; p. 1041-1047</subfield>
    </datafield>
  </record>
</collection>