Search

Immunité de détecteurs électroniques de personnel aux perturbations électromagnétiques

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Immunité de détecteurs électroniques de personnel aux perturbations électromagnétiques</title>
</titleInfo>
<titleInfo type="alternative">
<title>Cahiers de notes documentaires</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080005368">
<namePart>Klein, R.</namePart>
<nameIdentifier>MAPA20080005368</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">fra</placeTerm>
</place>
<dateIssued encoding="marc">1995</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">fre</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">Trois familles de dispositifs ont été testés: détecteurs périmétriques, détecteurs proximétriques, détecteurs de zone. Il leur a été appliqué des perturbations électromagnétiques, rayonnées, ou conduites, et des décharges électrostatiques. Il est trouvé une grande disparité dans les niveaux d'immunité mesurés. Les résultats montrent que la faiblesse de niveau d'immunité mesurés. Les résultats montrent que la faiblesse du niveau d'immunité de certains dispositifs les disqualifie pour les fonctions de contrôle/commande de processus industriels. Les dispositifs présentant les meilleurs résultats se caractérisent par leur utilisation relativement ancienne et leur technologie stabilisée et éprouvée</abstract>
<note type="statement of responsibility">R. Klein</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080629724">
<topic>Seguridad e higiene en el trabajo</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080614942">
<topic>Prevención de accidentes</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080604011">
<topic>Sistemas de seguridad</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080616786">
<topic>Dispositivos de seguridad</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080629823">
<topic>Sistemas de detección automáticos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080613204">
<topic>Campos electromagnéticos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080543815">
<topic>Ensayos</topic>
</subject>
<classification authority="">871</classification>
<relatedItem type="host">
<titleInfo>
<title>Cahiers de notes documentaires</title>
</titleInfo>
<originInfo>
<publisher>Paris</publisher>
</originInfo>
<part>
<text>nº 159, 2e. trimestre 1995 ; p. 251-264</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">950727</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418120816.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071023089</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>