Search

Controlling smoke in tunnel fires

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Controlling smoke in tunnel fires</title>
</titleInfo>
<titleInfo type="alternative">
<title>Fire prevention</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080123598">
<namePart>Bettis, Richard</namePart>
<nameIdentifier>MAPA20080123598</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">1995</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">Fires in tunnels are rare occurrences, but people planning and operating tunnels, or working with the emergency services, need to prepare for every eventuality. One of the main concerns in a tunnel fire is where the smoke will go. In some cases there will be shafts to the surface at intervals along the tunnel length, allowing smoke to escape. Often ventilation systems will be provided to supply fresh air for people and vehicles, and these too can take smoke out of the tunnel. Tunnels may have "transverse" systems where fresh air enters the tunnel and stale air is extracted along the whole length. The "worst case" fire scenario identified by Eurotunnel and the CTSA was a fire on a vehicle being carried on one of Eurotunnel's purpose-built HGV shuttles</abstract>
<note type="statement of responsibility">Richard Bettis</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080617424">
<topic>Investigación sobre fuego</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080545611">
<topic>Túneles</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560997">
<topic>Ventilación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080592097">
<topic>Movimiento de humos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080612597">
<topic>Sistemas de ventilación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080571566">
<topic>Casos prácticos</topic>
</subject>
<classification authority="">812.4</classification>
<relatedItem type="host">
<titleInfo>
<title>Fire prevention</title>
</titleInfo>
<originInfo>
<publisher>London</publisher>
</originInfo>
<identifier type="local">MAP20077000260</identifier>
<part>
<text>nº 280, June 1995 ; p. 19-22</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">950727</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418120817.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071023103</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>