Laboratory work with automatic pipettes : a study on how pipetting affects the thumb
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071024784</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418121127.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">960509e19950501gbr|||| | |00010|eng d</controlfield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">875</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080263607</subfield>
<subfield code="a">Fredriksson, Kerstin</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Laboratory work with automatic pipettes</subfield>
<subfield code="b">: a study on how pipetting affects the thumb</subfield>
<subfield code="c">Kerstin Fredriksson</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The aim of this study was to assess the strain that is exerted on the thumb when working with automatic pipettes. It is concluded, that some form of automation ought to be taken into consideration if the amount of pipetting work tends to increase. The pipettes should be constructed with as little button resistance as possible and the handle should be designed to fit different hand sizes</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080550653</subfield>
<subfield code="a">Ergonomía</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080610838</subfield>
<subfield code="a">Extremidades superiores</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080591717</subfield>
<subfield code="a">Lesiones musculares</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080611484</subfield>
<subfield code="a">Material de laboratorio</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080563134</subfield>
<subfield code="a">Laboratorios</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">Ergonomics</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">Ergonomics</subfield>
<subfield code="d">London and Washington</subfield>
<subfield code="g">Vol. 38, nº 5, May 1995 ; p. 1067-1073</subfield>
</datafield>
</record>
</collection>