Search

Retro-fitting sprinklers in the Nat West Tower

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071026275</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418121410.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">961115e19960301gbr||||    | |00010|eng d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">813.2</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080196097</subfield>
      <subfield code="a">Johnson, David A.</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Retro-fitting sprinklers in the Nat West Tower</subfield>
      <subfield code="c">David A. Johnson</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">The bishopsgate bombing in 1990 caused severe damage to the NatWest Tower but it provided the opportunity to upgrade safety systems in one of London's more complex high-rise landmarks. The author reports on the progress of the sprinkler retro-fit project</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080620424</subfield>
      <subfield code="a">Seguridad contra incendios</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080608415</subfield>
      <subfield code="a">Rociadores automáticos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080608699</subfield>
      <subfield code="a">Sistemas de rociadores</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080603984</subfield>
      <subfield code="a">Sistemas de extinción</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080613884</subfield>
      <subfield code="a">Edificios de gran altura</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080562663</subfield>
      <subfield code="a">Gran Bretaña</subfield>
    </datafield>
    <datafield tag="740" ind1="0" ind2=" ">
      <subfield code="a">Fire prevention</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="w">MAP20077000260</subfield>
      <subfield code="t">Fire prevention</subfield>
      <subfield code="d">London</subfield>
      <subfield code="g">nº 287, March 1996 ; p. 29-30</subfield>
    </datafield>
  </record>
</collection>