Search

Temporal variation in the iluminance level of stimuli displayed on a cathode-ray monitor : effects on performance on a visual vigilance task

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Temporal variation in the iluminance level of stimuli displayed on a cathode-ray monitor</title>
<subTitle>: effects on performance on a visual vigilance task</subTitle>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080062866">
<namePart>Blanco, M. J.</namePart>
<nameIdentifier>MAPA20080062866</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080028497">
<namePart>Leirós, Luz</namePart>
<nameIdentifier>MAPA20080028497</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">gbr</placeTerm>
</place>
<dateIssued encoding="marc">2000</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
</physicalDescription>
<abstract>This paper assesses the extent to which the sensitivity decrement frecuently observed in vigilance tasks is affected by temporal variations in the luminance level of the stimuli displayed on the screen of cathode'ray tube (CRT) monitor. The results indicate that the vigilance decrement is modulated by temporal fluctuations of the luminance of the monitor screen, which is used to display the stimuli. However, the relationship between both variables is not simple: the largest sensitivity decrement was not associated with the largest luminance decrement, but to a medium luminance decrement</abstract>
<note type="statement of responsibility">Manuel J. Blanco and Luz Leirós</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080550653">
<topic>Ergonomía</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080623326">
<topic>Pantallas catódicas de datos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080612917">
<topic>Tubo de rayos catódicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080558833">
<topic>Iluminación</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080577520">
<topic>Pruebas visuales</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080559960">
<topic>Ordenadores</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080610623">
<topic>Ensayos de sensibilidad</topic>
</subject>
<classification authority="">875</classification>
<relatedItem type="host">
<titleInfo>
<title>Ergonomics</title>
</titleInfo>
<originInfo>
<publisher>London [etc.]</publisher>
</originInfo>
<part>
<text>Vol. 43 nº 2, February 2000 ; p. 239-251</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">010629</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418122932.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071501745</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>