Método FREMAP FTIR-lectura directa para el análisis de sílice cristalina, en fracción respirable
<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Método FREMAP FTIR-lectura directa para el análisis de sílice cristalina, en fracción respirable</title>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080311063">
<namePart>Serrador Ramo, Joaquín</namePart>
<nameIdentifier>MAPA20080311063</nameIdentifier>
</name>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080342371">
<namePart>Sempere Fenollo, Lorenzo</namePart>
<nameIdentifier>MAPA20080342371</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">esp</placeTerm>
</place>
<dateIssued encoding="marc">2002</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
<internetMediaType>application/pdf</internetMediaType>
</physicalDescription>
<abstract>Actualmente, la evaluación y el control de los contaminantes en el medio ambiente es una realidad que forma parte de nuestra cultura laboral. El establecimiento de concentraciones ambientales de referencia que garanticen la salud de los trabajadores y la vigilancia en el cumplimiento de las mismas, implican y responsabilizan al químico analista en el desarrollo de métodos eficace para la determinación de sustancias tóxicas. Entre las enfermedades profesionales con carácter irreversible cabe destacar la neumoconiosis producida por la exposición al cuarzo</abstract>
<note type="statement of responsibility">Joaquín Serrador Ramo, Lorenzo Sempere Fenoll</note>
<note>Primer Premio concedido por la Association of Environmental Sciences and Techniques, en el VII International Symposium on Analytical Methodology in the Environmental Field, Valladolid, 20-22 marzo 2002</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080560850">
<topic>Toxicología</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080542313">
<topic>Sílice</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080619480">
<topic>Enfermedades profesionales</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080605278">
<topic>Contaminantes químicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080566593">
<topic>Neumoconiosis</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080591960">
<topic>Métodos de análisis</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>Mapfre seguridad</title>
</titleInfo>
<originInfo>
<publisher>Madrid</publisher>
</originInfo>
<identifier type="local">MAP20160012439</identifier>
<part>
<text>nº 86, 2º trimestre 2002 ; p. 19-25</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">020716</recordCreationDate>
<recordChangeDate encoding="iso8601">20191223101033.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071502599</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>