No flies on us
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071504967</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418124439.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">040223e20040101gbr|||| | |00010|eng d</controlfield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">813.3</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080060077</subfield>
<subfield code="a">Adams, Elaine</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">No flies on us</subfield>
<subfield code="c">Elaine Adams</subfield>
</datafield>
<datafield tag="520" ind1="8" ind2=" ">
<subfield code="a">A flea collar trial in Shropshire aimed at preventing thunder flies from triggering false alarms has been hailed an owerwhelming success. A trial, launched by Shropshire Fire and Rescue Service in 2003, has shown that the chemical used in pet flea collars can repel thrips from smoke detectors, dramatically reducing the number of false alarms caused by such flies</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080620424</subfield>
<subfield code="a">Seguridad contra incendios</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080568948</subfield>
<subfield code="a">Falsas alarmas</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080547707</subfield>
<subfield code="a">Insectos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080630614</subfield>
<subfield code="a">Sistemas de detección de incendios</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080575595</subfield>
<subfield code="a">Detección y alarma</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="w">MAP20077000260</subfield>
<subfield code="t">Fire prevention</subfield>
<subfield code="d">London</subfield>
<subfield code="g">January 2004 ; p. 24-25</subfield>
</datafield>
</record>
</collection>