The Measurement of ventilation parameters by means of tracer gas techniques and a microcomputer

Fichero PDF / PDF file
Section: Articles
Title: The Measurement of ventilation parameters by means of tracer gas techniques and a microcomputer / R. Niemelä, E. Toppila and A. TossavainenAuthor: Niemelä, R.
Notes: Sumario: A tracer method was developed for the evaluation of workplace ventilation. Nitrous oxide or freon was used of the tracer. The concentration of the tracer gas was measured with an infra-red analyser. The versatility of the tracer technique for industrial hygiene applications was improved by the use of a microcomputer for data calculation, display and storage. Three applications are presented: determination of the capture efficiency of a local exhaust hood; the evaluation of the air leakage of a room; and measurement of the local ventilation rates in a la large industrial plantRelated records: En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 2, 1984 ; p. 203-210Materia / lugar / evento: Higiene industrial Contaminación atmosférica Control de la contaminación Ventilación Aire Métodos de análisis Sistemas informáticos Ordenadores Otros autores: Toppila, E.
Tossavainen, A.
Secondary titles: Título: The Annals of occupational hygiene
Other categories: 872