Búsqueda

Evaluation of the impact on non-linear power on wiring requirements for commercial buildings : final report

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Evaluation of the impact on non-linear power on wiring requirements for commercial buildings</title>
<subTitle>: final report</subTitle>
</titleInfo>
<name type="personal" usage="primary" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20110021023">
<namePart>Schoene, Jens</namePart>
<nameIdentifier>MAPA20110021023</nameIdentifier>
</name>
<name type="corporate" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20100050293">
<namePart>Fire Protection Research Foundation</namePart>
<nameIdentifier>MAPA20100050293</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">usa</placeTerm>
</place>
<issuance>monographic</issuance>
<place>
<placeTerm type="text">Quincy</placeTerm>
</place>
<publisher>The Fire Protection Research Foundation</publisher>
<dateIssued>2011</dateIssued>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">eng</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
</physicalDescription>
<abstract displayLabel="Summary">The recent movement toward lighting systems, solid state technology, and renewable energy technologies has resulted in an increase in non linear power to building wiring systems. Non-linear power has an impact on various safety provisions of the National Electrical Code, including, for example: (a) harmonics in neutral conductors; (b) load calculations; (c) integration of non-linear loads on multi-wire branch circuits; and (d) over-current protection and AFCI and GFCI devices. This projects goals was to provide users of the NEC and NFPA 70B with guidance on this issue. The study reviews research relevant to safety and serviceability issues, provides case study examples of harmonic surveys, and provides guidance and recommended further studies to inform the NEC and NFPA 70B</abstract>
<note type="statement of responsibility">prepared by Jens Schoene</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080620424">
<topic>Seguridad contra incendios</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080593384">
<topic>Seguridad eléctrica</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080589516">
<topic>Centros comerciales</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080584849">
<topic>Edificios públicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080579234">
<topic>Cables eléctricos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080558833">
<topic>Iluminación</topic>
</subject>
<classification authority="">813.1</classification>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">110706</recordCreationDate>
<recordChangeDate encoding="iso8601">20110706125657.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20110045272</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>