Búsqueda

Development of real-time particulate and toxic gas sensors for firefighter health and safety

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000cam a22000004b 4500</leader>
    <controlfield tag="001">MAP20190027625</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20190925153736.0</controlfield>
    <controlfield tag="008">120206s2019    usa||||       ||| ||eng d</controlfield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
      <subfield code="d">MAP</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">813</subfield>
    </datafield>
    <datafield tag="100" ind1="1" ind2=" ">
      <subfield code="0">MAPA20190013185</subfield>
      <subfield code="a">Takahashi, Fumiaki</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="0">
      <subfield code="a">Development of real-time particulate and toxic gas sensors for firefighter health and safety</subfield>
      <subfield code="c">Fumiaki Takahashi</subfield>
    </datafield>
    <datafield tag="260" ind1=" " ind2=" ">
      <subfield code="a">Quincy</subfield>
      <subfield code="b">The Fire Protection Research Foundation</subfield>
      <subfield code="c">2019</subfield>
    </datafield>
    <datafield tag="300" ind1=" " ind2=" ">
      <subfield code="a">9 p. </subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Removal of respiratory protection during activities such as fire overhaul and wildland fire fighting can expose firefighters to unknown toxicants. The preliminary study indicates evidence to justify the needs for simultaneous monitoring of particulates (including ultrafines), aldehydes (formaldehyde, acrolein), and hydrocarbons (benzene) in addition to the CO levels, as they frequently exceed the exposure limits and lead to severe health issues in firefighters. This project will focus on developing prototypes of compact, highly sensitive, real-time particulate/gas detection systems to reduce the number of firefighter fatalities and injuries. The sensors will alert the firefighters of hazards in the air.</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="1">
      <subfield code="0">MAPA20080620424</subfield>
      <subfield code="a">Seguridad contra incendios</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080565817</subfield>
      <subfield code="a">Gases tóxicos</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080546298</subfield>
      <subfield code="a">Bomberos</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080549039</subfield>
      <subfield code="a">Sensores</subfield>
    </datafield>
    <datafield tag="650" ind1=" " ind2="4">
      <subfield code="0">MAPA20080629724</subfield>
      <subfield code="a">Seguridad e higiene en el trabajo</subfield>
    </datafield>
    <datafield tag="710" ind1="2" ind2=" ">
      <subfield code="0">MAPA20100050293</subfield>
      <subfield code="a">Fire Protection Research Foundation</subfield>
    </datafield>
  </record>
</collection>