Les Transformateurs aux P.C.B. (pyralènes) : fiche pratique de sécurité
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071015172</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418114111.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">931026e19880401fra|||| | |00010|fre d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800001740</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="4">
<subfield code="a">Les Transformateurs aux P.C.B. (pyralènes)</subfield>
<subfield code="b">: fiche pratique de sécurité</subfield>
<subfield code="c">J.C. Gilet</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">Caractéristiques des diélectriques aux PCB -- Risques toxicologiques -- Risques liés à l'utilisation des transformateurs aux PCB -- Comment reconnaître un transformateur au PCB -- Quantités mises en oeuvre -- Gestion des déchets -- Réglamentation et mesures de prévention -- Maintenance et réparation sur site -- Mesures à prendre en cas d'accident</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080552824</subfield>
<subfield code="a">Toxicidad</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080570484</subfield>
<subfield code="a">Riesgo laboral</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080536800</subfield>
<subfield code="a">PCB</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080614942</subfield>
<subfield code="a">Prevención de accidentes</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080560393</subfield>
<subfield code="a">Reglamentos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080574185</subfield>
<subfield code="a">Transformadores</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080629724</subfield>
<subfield code="a">Seguridad e higiene en el trabajo</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080639310</subfield>
<subfield code="a">Francia</subfield>
</datafield>
<datafield tag="740" ind1="0" ind2=" ">
<subfield code="a">Travail & sécurité</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="w">MAP20077000314</subfield>
<subfield code="t">Travail & sécurité</subfield>
<subfield code="d">Paris</subfield>
<subfield code="g">nº 4, Avril 1988 ; p. 227-230</subfield>
</datafield>
</record>
</collection>