Búsqueda

Caractéristiques acoustiques des locaux industriels : calcul prévisionnel des niveaux sonores en atelier

<?xml version="1.0" encoding="UTF-8"?><modsCollection xmlns="http://www.loc.gov/mods/v3" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/mods/v3 http://www.loc.gov/standards/mods/v3/mods-3-8.xsd">
<mods version="3.8">
<titleInfo>
<title>Caractéristiques acoustiques des locaux industriels</title>
<subTitle>: calcul prévisionnel des niveaux sonores en atelier</subTitle>
</titleInfo>
<titleInfo type="alternative">
<title>Cahiers de notes documentaires</title>
</titleInfo>
<name type="personal" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080028398">
<namePart>Leblond, H.</namePart>
<nameIdentifier>MAPA20080028398</nameIdentifier>
</name>
<typeOfResource>text</typeOfResource>
<originInfo>
<place>
<placeTerm type="code" authority="marccountry">fra</placeTerm>
</place>
<dateIssued encoding="marc">1978</dateIssued>
<issuance>serial</issuance>
</originInfo>
<language>
<languageTerm type="code" authority="iso639-2b">fre</languageTerm>
</language>
<physicalDescription>
<form authority="marcform">print</form>
<form authority="marccategory">microform</form>
</physicalDescription>
<abstract displayLabel="Summary">L'étude, dont les premiers résultats sont présentés dans cette note, comprend une partie expérimentale et une partie théorique. L'étude expérimentale a consisté à rassembler des données précises concernant les propriétés acoustiques d'une cinquentaine de locaux industriels et en particulier à mesurer la décroissance du bruit en fonction de la distance qui sépare le point de mesure de la source de bruit. Parallèlement, des programmes de calcul ont été mis au point pour calculer le niveau sonore qui s'établit en différents points d'une salle par suite de la présence dans la salle d'une source sonore</abstract>
<note type="statement of responsibility">H. Leblond... [et al.]</note>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080585679">
<topic>Higiene industrial</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080600488">
<topic>Contaminantes físicos</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080539740">
<topic>Ruido</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080569730">
<topic>Nivel de ruido</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080588946">
<topic>Ambiente de trabajo</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080582241">
<topic>Recintos cerrados</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080579746">
<topic>Control del ruido</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080547127">
<topic>Estudios</topic>
</subject>
<subject authority="lcshac" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="MAPA20080639310">
<topic>Francia</topic>
</subject>
<classification authority="">872</classification>
<relatedItem type="host">
<titleInfo>
<title>Cahiers de notes documentaires</title>
</titleInfo>
<originInfo>
<publisher>Paris</publisher>
</originInfo>
<part>
<text>nº 90, 1er. trimestre 1978 ; p. 13-36</text>
</part>
</relatedItem>
<recordInfo>
<recordContentSource authority="marcorg">MAP</recordContentSource>
<recordCreationDate encoding="marc">931122</recordCreationDate>
<recordChangeDate encoding="iso8601">20080418114346.0</recordChangeDate>
<recordIdentifier source="MAP">MAP20071015814</recordIdentifier>
<languageOfCataloging>
<languageTerm type="code" authority="iso639-2b">spa</languageTerm>
</languageOfCataloging>
</recordInfo>
</mods>
</modsCollection>