The Analysis of lagging materials for asbestos : CEGB procedures
Contenido multimedia no disponible por derechos de autor o por acceso restringido. Contacte con la institución para más información.
Tag | 1 | 2 | Valor |
---|---|---|---|
LDR | 00000nab a2200000 i 4500 | ||
001 | MAP20071017272 | ||
003 | MAP | ||
005 | 20080418115010.0 | ||
007 | hzruuu---uuuu | ||
008 | 940210s1979 gbr|||| | |00010|eng d | ||
035 | $a6800003176 | ||
040 | $aMAP$bspa | ||
084 | $a872 | ||
100 | 1 | $0MAPA20080018108$aWard, D.L. | |
245 | 1 | 4 | $aThe Analysis of lagging materials for asbestos$b: CEGB procedures$cD.L. Ward |
520 | $aThe Central Electricity Generating Board has used large quantities of a variety of thermal insulation materials on over 200 power stations; some of those materials contained asbestos. A cas is prsented for a nationally agreed standard for sampling and analysis of thermal insulation and other materials that may contain asbestos | ||
610 | 2 | 7 | $0MAPA20080458256$aCentral Electricity Generating Board |
650 | 1 | 1 | $0MAPA20080585679$aHigiene industrial |
650 | 1 | 1 | $0MAPA20080605278$aContaminantes químicos |
650 | 1 | 1 | $0MAPA20080616441$aContaminación atmosférica |
650 | 1 | 1 | $0MAPA20080551797$aMuestreos |
650 | 1 | 1 | $0MAPA20080597511$aMateriales aislantes |
650 | 1 | 1 | $0MAPA20080542832$aAmianto |
650 | 1 | 1 | $0MAPA20080588939$aAislamiento térmico |
650 | 1 | 1 | $0MAPA20080591960$aMétodos de análisis |
740 | 4 | $aThe Annals of occupational hygiene | |
773 | 0 | $tThe Annals of occupational hygiene$dOxford [etc.]$gnº 3, 1979 ; p. 319-323 |