Performance measurements on a powered air-purifying respirator made during actual field use in silica bagging operation
<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
<record>
<leader>00000nab a2200000 i 4500</leader>
<controlfield tag="001">MAP20071017429</controlfield>
<controlfield tag="003">MAP</controlfield>
<controlfield tag="005">20080418115046.0</controlfield>
<controlfield tag="007">hzruuu---uuuu</controlfield>
<controlfield tag="008">940217s1983 gbr|||| | |00010|eng d</controlfield>
<datafield tag="035" ind1=" " ind2=" ">
<subfield code="a">6800003285</subfield>
</datafield>
<datafield tag="040" ind1=" " ind2=" ">
<subfield code="a">MAP</subfield>
<subfield code="b">spa</subfield>
</datafield>
<datafield tag="084" ind1=" " ind2=" ">
<subfield code="a">872</subfield>
</datafield>
<datafield tag="100" ind1="1" ind2=" ">
<subfield code="0">MAPA20080172497</subfield>
<subfield code="a">Myers, Warren R.</subfield>
</datafield>
<datafield tag="245" ind1="1" ind2="0">
<subfield code="a">Performance measurements on a powered air-purifying respirator made during actual field use in silica bagging operation</subfield>
<subfield code="c">Warren R. Myers and Michael J. Peach</subfield>
</datafield>
<datafield tag="520" ind1=" " ind2=" ">
<subfield code="a">The performance of Powered Air-Purifying Respirators (PAPR) has been measured in actual field use conditions that exist for silica dust baggers. The data indicate that the laboratory performance of this PAPR is better than its field performance measured during a silica bagging operation. A protection factor classification of 1000 is normally assigned to PAPRs; however, the workplace protection factors measured on this tight fitting facepiece PAPR ranged from 16 to 215. Reasons for the difference between the assigned protection factor and workplace protection factors measured with these devices are discussed</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080585679</subfield>
<subfield code="a">Higiene industrial</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080605278</subfield>
<subfield code="a">Contaminantes químicos</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080542313</subfield>
<subfield code="a">Sílice</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080573348</subfield>
<subfield code="a">Polvo de sílice</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080537807</subfield>
<subfield code="a">PAPR</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080601393</subfield>
<subfield code="a">Equipos respiratorios</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080543969</subfield>
<subfield code="a">Filtros</subfield>
</datafield>
<datafield tag="650" ind1="1" ind2="1">
<subfield code="0">MAPA20080628048</subfield>
<subfield code="a">Equipos de protección individual</subfield>
</datafield>
<datafield tag="700" ind1="1" ind2=" ">
<subfield code="0">MAPA20080202941</subfield>
<subfield code="a">Peach, Michael J.</subfield>
</datafield>
<datafield tag="740" ind1="4" ind2=" ">
<subfield code="a">The Annals of occupational hygiene</subfield>
</datafield>
<datafield tag="773" ind1="0" ind2=" ">
<subfield code="t">The Annals of occupational hygiene</subfield>
<subfield code="d">Oxford [etc.]</subfield>
<subfield code="g">nº 3, 1983 ; p. 251-259</subfield>
</datafield>
</record>
</collection>