Búsqueda

Inhalable, total and respirable dust : a field study

Fichero PDF / PDF file
MAP20071017524
Verma, Dave K.
Inhalable, total and respirable dust : a field study / D.K. Verma
Sumario: Inhalable dust, total dust and respirable dust by cyclone and horizontal elutriator were measured in a side area sampling programme at eight selected ferrous and non-ferrous foundries. Forty sets of samples were collected and the relatioships between four different dust measurements were examined. In the foundry environments sruveyed, total dust correlated highly with the inhalable dust concentration. The MRE elutriator operating at 2.5 l. min-1 flow rate, matching the BMRC respirable dust criterion, generally collected more dust by weight per m3 air than the 10 mm nylon cyclone, operating at 1.7 l. min-1 matching the ACGIH respirable dust criterion
En: The Annals of occupational hygiene. - Oxford [etc.]. - nº 2, 1984 ; p. 163-172
1. Higiene industrial . 2. Contaminantes químicos . 3. Polvo . 4. Contaminación atmosférica . 5. Control de la contaminación . 6. Ambiente de trabajo . 7. Muestreos . 8. Fundición . I. Título. II. Título: The Annals of occupational hygiene.