Búsqueda

Capture efficiency of flanged circular local exhaust hoods

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071017616
003  MAP
005  20080418115124.0
007  hzruuu---uuuu
008  940224s1986 gbr|||| | |00010|eng d
035  ‎$a‎6800003416
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
1001 ‎$0‎MAPA20080191696‎$a‎Flynn, Michael R.
24510‎$a‎Capture efficiency of flanged circular local exhaust hoods‎$c‎Michael R. Flynn and Michael J. Ellenbecker
520  ‎$a‎The concept of capture efficiency as a design parameter for Local Exhaust Ventilation systems is presented. A theoretical model, based on computer-generated streamline maps, is developed for predicting the capture efficiency of a flanged circular hood operating with a crossdraught blowing perpendicular to the centreline. Potential applications of capture efficiency to the design and improvement of Local Exhaust Ventilation systems are discussed
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080591113‎$a‎Gases contaminantes
65011‎$0‎MAPA20080552923‎$a‎Velocidad
65011‎$0‎MAPA20080537210‎$a‎Aire
65011‎$0‎MAPA20080560997‎$a‎Ventilación
65011‎$0‎MAPA20080612597‎$a‎Sistemas de ventilación
65011‎$0‎MAPA20080621186‎$a‎Control de la contaminación
7001 ‎$0‎MAPA20080317249‎$a‎Ellenbecker, Michael J.
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 4, 1986 ; p. 497-513