Búsqueda

Evaluation of airborne asbestos concentrations using TEM and SEM during residential water tank removal

Fichero PDF / PDF file
Registro MARC
Tag12Valor
LDR  00000nab a2200000 i 4500
001  MAP20071017738
003  MAP
005  20080418115149.0
007  hzruuu---uuuu
008  940307s1987 gbr|||| | |00010|eng d
035  ‎$a‎6800003421
040  ‎$a‎MAP‎$b‎spa
084  ‎$a‎872
24510‎$a‎Evaluation of airborne asbestos concentrations using TEM and SEM during residential water tank removal‎$c‎P.N. Breysse... [et al.]
520  ‎$a‎The purpose of this study was to evaluate three different analytical techniques for estimating concentrations of airborne asbestos during a short-term removal operation. Samples were collected during the removal of asbestos-insulated water tanks. Airborne samples collected for phase contrast optical, and scanning and transmission electron, microscopic (PCOM, SEM and TEM) analysis, using direct transfer techniques
65011‎$0‎MAPA20080585679‎$a‎Higiene industrial
65011‎$0‎MAPA20080605278‎$a‎Contaminantes químicos
65011‎$0‎MAPA20080616441‎$a‎Contaminación atmosférica
65011‎$0‎MAPA20080621186‎$a‎Control de la contaminación
65011‎$0‎MAPA20080542832‎$a‎Amianto
65011‎$0‎MAPA20080591960‎$a‎Métodos de análisis
65011‎$0‎MAPA20080537005‎$a‎SEM
65011‎$0‎MAPA20080537050‎$a‎TEM
65011‎$0‎MAPA20080537838‎$a‎PCOM
65011‎$0‎MAPA20080563387‎$a‎Microscopios
65011‎$0‎MAPA20080579890‎$a‎Depósitos de agua
65011‎$0‎MAPA20080551797‎$a‎Muestreos
7001 ‎$0‎MAPA20080063405‎$a‎Breysse, P.N.
7404 ‎$a‎The Annals of occupational hygiene
7730 ‎$t‎The Annals of occupational hygiene‎$d‎Oxford [etc.]‎$g‎nº 2, 1989 ; p. 243-256