MAP20071017751González-Fernández, EnriqueComparison of AIA and NIOSH methods for evaluating asbestos fibre measurements in the workplace / E. González-Fernández, Paulino D. de la Osa and Félix R. MartínSumario: Industrial hygiene evaluation of airborne asbestos dust by the membrane-filter/phase-contrast optical microscope method has been adopted by the most countries, but detailed procedures differ. In the present work sampling results obtained in a asbestos cement factory by the NIOSH Analytical Method P & CAM 239 and the AIA Recommended Technical Method No. 1 have been compared. The concentrations measured by the AIA method were on average less than those determined by the NIOSH method, the mean ratio AIA7NIOSH being 0.29. Analysis of variance showed the difference to be statistically significantEn: The Annals of occupational hygiene. - Oxford [etc.]. - nº 3, 1987 ; p. 363-3731. AIA. 2. National Institute for Occupational Safety and Health. 3. Higiene industrial. 4. Contaminantes químicos. 5. Amianto. 6. Fibra mineral. 7. Métodos de análisis. 8. Estudios comparativos. 9. Contaminación atmosférica. 10. Muestreos. I. Osa, Paulino D. de la. II. Martín, Félix R.. III. Título. IV. Título: The Annals of occupational hygiene.