Búsqueda

The Application of test data in the selection and use of gloves against chemicals

<?xml version="1.0" encoding="UTF-8"?><collection xmlns="http://www.loc.gov/MARC21/slim" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd">
  <record>
    <leader>00000nab a2200000 i 4500</leader>
    <controlfield tag="001">MAP20071017798</controlfield>
    <controlfield tag="003">MAP</controlfield>
    <controlfield tag="005">20080418115205.0</controlfield>
    <controlfield tag="007">hzruuu---uuuu</controlfield>
    <controlfield tag="008">940308e19900201gbr||||    | |00010|eng d</controlfield>
    <datafield tag="035" ind1=" " ind2=" ">
      <subfield code="a">6800003081</subfield>
    </datafield>
    <datafield tag="040" ind1=" " ind2=" ">
      <subfield code="a">MAP</subfield>
      <subfield code="b">spa</subfield>
    </datafield>
    <datafield tag="084" ind1=" " ind2=" ">
      <subfield code="a">871</subfield>
    </datafield>
    <datafield tag="245" ind1="1" ind2="4">
      <subfield code="a">The Application of test data in the selection and use of gloves against chemicals</subfield>
      <subfield code="c">P. Leinster... [et al.]</subfield>
    </datafield>
    <datafield tag="520" ind1=" " ind2=" ">
      <subfield code="a">Within recent years there have been a number of papers on the testing of protective clothing materials for degradation, penetration and permeation by chemicals. However, little guidance has been provided concerning the practical application of such data in the selection and use of gloves. A scheme is proposed for the selection of appropiate gloves and for deciding whether they should be reused. This takes into account the toxic properties of the chemical involved, the type of activity being undertaken and the degree of protection afforded by a particular material as indicated by data obtained from standard tests</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080629724</subfield>
      <subfield code="a">Seguridad e higiene en el trabajo</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080628048</subfield>
      <subfield code="a">Equipos de protección individual</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080585679</subfield>
      <subfield code="a">Higiene industrial</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080605278</subfield>
      <subfield code="a">Contaminantes químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080587079</subfield>
      <subfield code="a">Productos químicos</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080601836</subfield>
      <subfield code="a">Guantes de protección</subfield>
    </datafield>
    <datafield tag="650" ind1="1" ind2="1">
      <subfield code="0">MAPA20080539948</subfield>
      <subfield code="a">Tests</subfield>
    </datafield>
    <datafield tag="700" ind1="1" ind2=" ">
      <subfield code="0">MAPA20080048723</subfield>
      <subfield code="a">Leinster, P.</subfield>
    </datafield>
    <datafield tag="740" ind1="4" ind2=" ">
      <subfield code="a">The Annals of occupational hygiene</subfield>
    </datafield>
    <datafield tag="773" ind1="0" ind2=" ">
      <subfield code="t">The Annals of occupational hygiene</subfield>
      <subfield code="d">Oxford [etc.]</subfield>
      <subfield code="g">nº 1, February 1990 ; p. 85-90</subfield>
    </datafield>
  </record>